Migration from OPC Classic to OPC UA – Effectively and Smoothly

espansione-dal-classico-opc-opc-ua-efficacemente-ed-uniformemente-P392837Softing’s OPC UA .NET Development Toolkits V1.10 now include backwards compatibility with OPC Classic applications and offer an attractive licensing model for the development of OPC UA software applications.

Users who plan to migrate from OPC Classic to OPC UA now have the possibility to develop OPC UA .NET clients and servers with Softing’s OPC UA .NET Toolkits V1.10, which communicate with the existing legacy OPC COM DA clients and servers. The investment is secured by Softing’s attractive licensing model which already includes the license entitlement to any number of OPC UA software applications developed with the toolkits.

The software package is accompanied with sample configuration tools and comprehensive documentation which guarantees a smooth integration of the UA based products into existing OPC Classic installations. A fully functional, limited runtime trial version as well as a detailed release note can be downloaded from the Softing Website.

For more than 15 years Softing has been a major supplier of OPC Development Toolkits to developers of OPC clients and servers around the world. The Softing OPC portfolio includes 18 versions of OPC Development Toolkits. Among them are OPC Classic Toolkits covering Data Access, Alarms & Events and XML-DA for Windows and Linux as well as Unified Architecture Toolkits for Windows in C++ and .NET and for Linux and VxWorks in C++.

 

website http://industrial.softing.com/

 

Nota: questo portale non è legato alle aziende e ai prodotti che vengono presentati da alcun rapporto di natura commerciale

Pannello operatore grafico tattile

pannello-operatore-grafico-tattile-P394253Disponibile nelle due versioni monocromo e a colori, offre una risoluzione a schermo di 320x240 pixel ed un sacco di caratteristiche e funzioni che danno maggiore flessibilità e capacità ai sistemi di controllo. Il modello a colori vanta uno schermo TFT che presenta 65.536 colori per una maggiore nitidezza, anziché i 256 colori più tipici a prezzi di questo livello. La versione monocromatica impiega uno schermo STN che offre 16 scale di grigio. Entrambe le versioni offrono caratteristiche quali retroilluminazione LED di lunga durata, funzioni a sfioramento analogiche, porta USB frontale, uno slot per scheda SD, protezione IP67f del pannello frontale e porta Ethernet.

 

website http://www.mitsubishi-automation.com/

 

Nota: questo portale non è legato alle aziende e ai prodotti che vengono presentati da alcun rapporto di natura commerciale



Update 1 per WinCC 7.2

E’ disponibile l’update 1 per WinCC 7.2 anche per versione ASIA scaricabile dal seguente link (FAQ 73443294) http://support.automation.siemens.com/WW/view/en/73443294 Leggere attentamente le informazioni di aggiornamento prima di procedere con sistemi in produzione.

WinCC V7.2 Tips&Tricks

Siemens ha recentemente pubblicato un interessante video (FAQ 74509647) che visualizza alcune delle nuove funzionalità presenti nella versione 7.2 di WinCC. Il video è visualizzabile al seguente link: http://support.automation.siemens.com/WW/view/en/74509647 Il video è anche scaricabile in formato zip.

Beckhoff: CP-Link 4: The One Cable Display Link

cp-collegamento-4-collegamento-dell-esposizione-cavo-P393767Beckhoff presented a technological highlight at Hannover Messe 2013: CP-Link 4 is the new connection technology for operating panels located up to 100 m away from the Industrial PC. The single-cable solution can be used to transfer video signals, USB 2.0 and the power supply in a standard CAT 7 cable, thus reducing cable and installation costs. A further benefit is the use of purely passive displays. The CP-Link 4 technology is supported by the new Beckhoff multi-touch panel series CP29xx-0010 (built-in version) and CP39xx-0010 (mounting arm version).

The new Beckhoff panel generation with industrial multi-touch display offers a wide range of display sizes and connection options. CP-Link 4 extends the product portfolio with simple, standards-based connection technology.

A big advantage of this transmission technology is the use of commercial CAT 7 cables. They are easy to install and are also available as drag chain versions. The standard plug connectors are field-configurable. Alternatively, pre-assembled cables are available as accessories. The plug-and-play connection makes commissioning very simple and convenient. CP-Link 4 requires no special software or drivers.

The CP-Link 4 technology is directly integrated in the passive panels of the multi-touch series. On the PC side, the connection can be made either via the PCIe module slot in the Industrial PC or via the CU8802 or CU8803 transmitter boxes. The following connection options are available:

The One Cable Display Link: In the single-cable solution, the DVI signal, USB 2.0 signal and 24 V power supply are transferred via a single cable. The CU8803 transmitter box provides the power supply for the Control Panel via the CAT 7 cable, which can be up to 100 m long. The CU8803 box can be connected to any PC via a DVI and USB cable and requires a 24 V supply.

The Two Cable Display Link: With this connection option DVI and USB 2.0 are transferred via a CAT 7 cable. The CU8802 transmitter box is connected to the PC via DVI and USB, or the C9900-E276 PCIe module is integrated in a Beckhoff IPC. The power supply is separate and is switchable, e.g. for emergency stop solutions with parallel wiring.


Beckhoff – the pioneer for industrial display connection technology

As a pioneer for industrial display connection technology, Beckhoff launched the first version of CP-Link as early as 1998. It enabled operating panels to be located away from the PC for the first time. Via two standard coaxial cables this version can be used to bridge a distance of up to 100 m between the PC and operator interface.

In 2006, Beckhoff presented the second generation of its display connection technology as a further innovation: surpassing the 5 m DVI/USB standard distance, the DVI/USB Extended technology, based on standard cables, enables distances of up to 50 m between Industrial PC and operating panel. The DVI/USB Extended 2.0 technology is offered with the new multi-touch panel series.

The CP-Link 3 concept is a pure software solution, using standard cable technologies for versatile connection of Panel PCs with an Industrial PC. It enables connection of up to 255 Ethernet Panels.

The collective expertise from 15 years of experience in the realisation of flexible visualisation and operating concepts is now bundled in the CP-Link 4 generation based on single-cable technology.

 

Website www.beckhoff.com

Nota: questo portale non è legato alle aziende e ai prodotti che vengono presentati da alcun rapporto di natura commerciale



ServiTecno annuncia la nuova release di Win-911

Disponibile la versione 7.14 del software Specter Instrumentsper la gestione degli allarmi in tempo reale

Win-911 è un potente sistema informativo per l'automazione industriale che gestisce i processi di notifica a distanza degli allarmi. La nuova release 7.14 offre un riepilogo degli allarmi web-based tramite app disponibili sia per sistemi operativi Android che per iPhone. Grazie a Mobile View, recentemente aggiunto a Mobile-911, è possibile accedere a Win-911 da qualsiasi browser. In questo modo gli utenti possono visualizzare gli allarmi all'interno di una rete o tramite Internet utilizzando applicazioni per smartphone o tramite qualsiasi browser web.

Prodotto da Specter Instruments e distribuito in Italia da ServiTecno, Win-911 è un'applicazione Windows per la generazione di allarmi pensata per notificare situazioni, eventi e problemi tramite email, telefoni fissi o cellulari. Win-911 lavora anche come gestore di allarmi, permettendo a chi risponde di agire sugli allarmi stessi e consentendo la generazione dei report. Win-911 è un valido complemento per ogni sistema SCADA, poiché può lavorare in combinazione con tutti i più conosciuti pacchetti software SCADA/HMI e con tutti gli altri software compatibili con OPC.

Win-911 presenta nuove funzioni e caratteristiche che ne rendono ancora più facile l'utilizzo e la connessione. La versione 7.14 include una connessione diretta con la piattaforma PanelView Plus di Rockwell. La Win-911 Machine Edition (ME) Direct Connect permette di configurare fino a 50 allarmi utilizzando il WIN-911/ME ActiveX Control incorporato in PanelView Plus.

website http://www.servitecno.it/

Nota: questo portale non è legato alle aziende e ai prodotti che vengono presentati da alcun rapporto di natura commerciale